Contact Now:sales@goldway.com.cn
Golden Way Scientific manufacturers millions of optics every year throughout our four global facilities. Join us as we take you through the creation of an aspheric lens, from molding to grinding to polishing, centering, and metrology.
Aspheric Manufacturing Capabilities | ||||
Commercial | Standard | Precision | Best Effort | |
Diameter | 10 – 120mm | 10 – 120mm | 10 – 120mm | 10 – 200mm |
Diameter Tolerance | -0.100mm | -0.05mm | -0.01mm | -0.005mm |
Asphere Figure Error (P-V) @ 633nm | 5 waves | 1 wave | 0.5 wave | 0.5 wave |
Vertex Radius (Asphere) | ±0.5% | ±0.1% | ±0.05% | ±0.05% |
Surface Profile Deviation | 1.5um | 1.5um | 1.0um | 0.5um |
Centering (Beam Deviation) | 5 arcmin | 3 arcmin | 1 arcmin | 0.5 arcmin |
Center Thickness Tolerance | ±0.100mm | ±0.050mm | ±0.030mm | ±0.010mm |
Surface Quality (Scratch Dig) | 80-50 | 60-40 | 40-20 | 20-10 |
Surface Roughness (RMS) | 5nm | 3nm | 1.5nm | 1nm |
Measurement parameters | EFL, R, Center Deviation, FFL, BFL, MTF, Wedge Angle (Parallelism) |
EFL test range | +1 ~ +2000mm -1 ~ -1500mm |
EFL measurement accuracy | 0.03% ~ 0.30% |
R,BFL test range | ±1mm ~ ±750mm |
R BFL measurement accuracy | 0.05% ~ 0.30% |
Center Deviation Test Range | ±1mm ~ ±2000mm |
Center deviation measurement accuracy | ±0.2um or ±2 arcsec |
Wedge angle (parallelism) measurement accuracy | ±1 arcsec |
Applications and Measurements | Contact spherical curvature radius measurement |
Curvature radius test range | L±6mm ~ ∞ |
Diameter of sample to be tested | 10 ~ 500mm |
Curvature Radius Measurement Accuracy | 0.005% |
Linear encoder working distance | ±30mm |
Linear encoder absolute accuracy |
0.05um |
Measurement mode | Reflection method to measure the angle between any two adjacent polished surfaces of a prism |
Measuring range | 0 ~ 360° |
Measurement accuracy |
Single measurement: 0.50" Multiple measurements: 0.20" |
Rotary encoder resolution | 0.036” |
Rotary encoder accuracy | 0.20” |
Standard lens diameter | 100mm |
Flat Standard Lens Accuracy | Lambda/20 @ 633nm |
Measurement repeatability | Lambda/100 @ 633nm |
Spherical standard lens F-number | F/0.65, F/1.6, F/3.3, F/7.0,F/1.0,F/10.7 |
Spherical Standard Lens Accuracy | Lambda/10 @ 633nm |
Applications and Measurements | Transmittance and reflectance measurement of planar components |
wavelength range | UV/VIS/IR (185nm ~ 3300nm) |
UVVis sub-band resolution | ≤0.05nm |
Infrared band resolution | ≤0.20nm |
Stray light@220nm& 340nm&370nm | ≤0.00007%T |
wavelength repeatability | ≤0.20nm |