Golden Way Scientific's beamsplitters are manufactured from a wide variety of SCHOTT, Ohara, and CDGM materials. Whether you require several beamsplitters for prototyping, a few dozen for pre-production, or large quantities for mass production, we can develop a solution tailored for your application. Some values may depend on material and the other required specifications.
Beamsplitter Manufacturing Capabilities | ||||
Attribute | Commercial | Standard | High Precision | Top Limit |
Dimensions | 2.00 - 200.00 mm | 2.00 - 200.00 mm | 2.00 - 100.00 mm | 2.00 - 100.00 mm |
Dimensional Tolerance | ±0.20mm | ±0.10mm | ±0.05mm | ±0.005mm |
Power @ 632.8nm | 3 waves | 1 waves | 0.1 waves | 0.05 waves |
Irregularity @ 632.8nm (rms) | 1 waves | 0.25 waves | 0.05 waves | 0.02 waves |
Surface Quality (Scratch Dig) | 80-50 | 60-40 | 20-10 | 10-5 |
Beam Deviation | ±5 arcmin | ±3 arcmin | ±0.5 arcmin | ±3 arcsec |
|Ts – Tp| (Broadband Non-Polarizing) | <10% | <5% | <5% | <3% |
|Ts – Tp| (Laser Line Non-Polarizing) | <15% | <5% | <3% | <1% |
Splitting Ratios (Non-Polarizing) | 50/50 to 90/10 | 50/50 to 90/10 | 50/50 to 90/10 | 50/50 to 90/10 |
Splitting Ratio Tolerance | ±15% | ±10% | ±5% | ±3% |
Extinction Ratio (Polarizing) | 500:1 | 1000:1 | > 1000:1 | > 2000:1 |
Wavelength Range | UV-16um | UV-16um | UV-14um | UV-12um |
Measurement parameters | EFL, R, Center Deviation, FFL, BFL, MTF, Wedge Angle (Parallelism) |
EFL test range | +1 ~ +2000mm -1 ~ -1500mm |
EFL measurement accuracy | 0.03% ~ 0.30% |
R,BFL test range | ±1mm ~ ±750mm |
R BFL measurement accuracy | 0.05% ~ 0.30% |
Center Deviation Test Range | ±1mm ~ ±2000mm |
Center deviation measurement accuracy | ±0.2um or ±2 arcsec |
Wedge angle (parallelism) measurement accuracy | ±1 arcsec |
Applications and Measurements | Contact spherical curvature radius measurement |
Curvature radius test range | L±6mm ~ ∞ |
Diameter of sample to be tested | 10 ~ 500mm |
Curvature Radius Measurement Accuracy | 0.005% |
Linear encoder working distance | ±30mm |
Linear encoder absolute accuracy |
0.05um |
Measurement mode | Reflection method to measure the angle between any two adjacent polished surfaces of a prism |
Measuring range | 0 ~ 360° |
Measurement accuracy |
Single measurement: 0.50" Multiple measurements: 0.20" |
Rotary encoder resolution | 0.036” |
Rotary encoder accuracy | 0.20” |
Standard lens diameter | 100mm |
Flat Standard Lens Accuracy | Lambda/20 @ 633nm |
Measurement repeatability | Lambda/100 @ 633nm |
Spherical standard lens F-number | F/0.65, F/1.6, F/3.3, F/7.0,F/1.0,F/10.7 |
Spherical Standard Lens Accuracy | Lambda/10 @ 633nm |
Applications and Measurements | Transmittance and reflectance measurement of planar components |
wavelength range | UV/VIS/IR (185nm ~ 3300nm) |
UVVis sub-band resolution | ≤0.05nm |
Infrared band resolution | ≤0.20nm |
Stray light@220nm& 340nm&370nm | ≤0.00007%T |
wavelength repeatability | ≤0.20nm |