Material: | Quartz Crystal |
Wavefront Distortion : | up to wave/10 @ 632.8nm |
Retardation Tolerance: | wave/500 |
Parallelism: | < 1 arcsec. |
Surface Quality: | up to 10-5 |
Clear Aperture: | >90% |
Coating: | upon requirement, high LIDT available |
Type | Feature | |
Zero Order | Cemented | Cemented by glue |
Better Temperature Bandwidth | ||
Wide Wavelength Bandwidth | ||
Moderate damage threshold | ||
Optical Contacted | No glue | |
Better Temperature Bandwidth | ||
Wide Wavelength Bandwidth | ||
Better damage threshold | ||
Good wavefront and parallelism | ||
Air Spaced | No glue, Mounted | |
Better Temperature Bandwidth | ||
Wide Wavelength Bandwidth | ||
High damage threshold | ||
True Zero Order | Cemented | Cemented by glue |
Better Temperature Bandwidth | ||
Wide Wavelength Bandwidth | ||
Moderate damage threshold | ||
Excellent retardation performance | ||
Single Plate | Single plate | |
Better Temperature Bandwidth | ||
Wide Wavelength Bandwidth | ||
High damage threshold | ||
Only 1310nm, 1550nm available | ||
Multi Order | Low Temperature Bandwidth | |
Low Wavelength Bandwidth | ||
High damage threshold | ||
Low cost | ||
Achromatic | Better Temperature Bandwidth | |
Very broad Wavelength Bandwidth | ||
Cemented and air spaced available |
Measurement parameters | EFL, R, Center Deviation, FFL, BFL, MTF, Wedge Angle (Parallelism) |
EFL test range | +1 ~ +2000mm -1 ~ -1500mm |
EFL measurement accuracy | 0.03% ~ 0.30% |
R,BFL test range | ±1mm ~ ±750mm |
R BFL measurement accuracy | 0.05% ~ 0.30% |
Center Deviation Test Range | ±1mm ~ ±2000mm |
Center deviation measurement accuracy | ±0.2um or ±2 arcsec |
Wedge angle (parallelism) measurement accuracy | ±1 arcsec |
Applications and Measurements | Contact spherical curvature radius measurement |
Curvature radius test range | L±6mm ~ ∞ |
Diameter of sample to be tested | 10 ~ 500mm |
Curvature Radius Measurement Accuracy | 0.005% |
Linear encoder working distance | ±30mm |
Linear encoder absolute accuracy |
0.05um |
Measurement mode | Reflection method to measure the angle between any two adjacent polished surfaces of a prism |
Measuring range | 0 ~ 360° |
Measurement accuracy |
Single measurement: 0.50" Multiple measurements: 0.20" |
Rotary encoder resolution | 0.036” |
Rotary encoder accuracy | 0.20” |
Standard lens diameter | 100mm |
Flat Standard Lens Accuracy | Lambda/20 @ 633nm |
Measurement repeatability | Lambda/100 @ 633nm |
Spherical standard lens F-number | F/0.65, F/1.6, F/3.3, F/7.0,F/1.0,F/10.7 |
Spherical Standard Lens Accuracy | Lambda/10 @ 633nm |
Applications and Measurements | Transmittance and reflectance measurement of planar components |
wavelength range | UV/VIS/IR (185nm ~ 3300nm) |
UVVis sub-band resolution | ≤0.05nm |
Infrared band resolution | ≤0.20nm |
Stray light@220nm& 340nm&370nm | ≤0.00007%T |
wavelength repeatability | ≤0.20nm |